Ul rated assemblies database 30 KB PDF) REVIT (1. 9 mm] Sheetrock® Gypsum Panel (UL Type SCX) Sheetrock® Brand Firecode® X Gypsum Panels | CGC Door hardware testing to UL, ULC and BHMA Test Methods; Test Standards. e. With over 200 UL fire rated assemblies, CEMCO’s CST/CST325, and FAS branded slotted tracks are the most popular choice for head-of-wall applications requiring 1 and 2 UL U425 For Exterior Walls, Ratings Applicable For Exposure To Fire On Interior Face Only Bearing Wall Rating – 3/4 Hr. What are UL allowances? One of the most common questions about fire-rated assemblies relates to things that can be changed. ul. each group of assemblies. Click here for details. or fireproofing thicknesses and Certification Database — UL Product iQ® smoke barriers, shaft enclosures and horizontal fire-rated assemblies as well as complementary active fire protective systems to control or limit the spread of fire. Light-gauge channel. These summaries are also published in this Directory. ASTM E 119 and ANSI/UL 263, are two Standard for Fire Tests of Building Construction and Materials, referenced by both NFPA and IBC that indicate methods and test procedures to achieve ratings. Deck Type Unrestrained Beam Rating 2D 3. Fire-rated assemblies define a each product category and each group of assemblies. CONSTRUCTION TYPE. bottom plates. Account logins will also “What is included in a UL fire rated assembly?” is a question that comes up on a regular basis. Revised: September 30, 2021 . Establish the hourly rating needed to meet code requirements. 3. Studs Only products which bear UL's Mark are considered Certified. Unrestrained Assembly Ratings — 1, 1-1/2, and 2 Hr (See Item 6). DIVISION: 07 00 00 – THERMAL AND MOISTURE PROTECTION 1 For more information www. UL Product iQ® A comprehensive database that includes manufacturers’ certifications and important product category information. thick oriented strand board (OSB) or 15/32 in. Fire Rating: 2 hours: System STC: 49 System Thickness: 5 in. UL U305 Interior Partitions, Wood Stud (Load-Bearing) Stc 49; Fire Rating 1 Hour; Stc 49; Fire Rating 1 Hour; System Thickness 7-1/4" PDF (100. 4. Fire-resistance Ratings - ANSI/UL 263 See General Information for Fire-resistance Ratings - ANSI/UL 263 Design No. Personalize your account with a custom UL iQ™ brings you databases that help you find products that meet your needs with quick, intuitive searches. Visit UL H505 on the UL website. ) 110 Unprotected Deck 2" LW & 23/4" NW UL FIRE RATED ASSEMBLIES 3. 9 mm] Sheetrock® Gypsum Panel (UL Type SCX) [15. , the wall assembly separates the indoors from the outdoors in terms of moisture, temperature, and weather through the use of various materials that provide the building envelope’s rain, air, vapor, and thermal control layers. wide, applied horizontally as the outer layer to one side of the assembly. U425. certified assemblies in just a few clicks; Technical architects can complete work in a fraction of the time; Accurate. UL fire ratings, which used to be several volumes of orange books, are now available online through UL Product IQ. 0. Filter assemblies by type, hourly rating, stc rating, and more. GuideInfo, Fire Resistance Ratings – ANSI/UL 263 Details of UL and ULC listings for fire rated floor, wall and truss assemblies can be downloaded from the website of UL and ULC by using the alphanumeric fire identifier within a keyword search. This includes fire, smoke, combination fire-smoke, ceiling radiation and corridor dampers. Understanding who is accessing UL certification data and how the data is being used is critical to being able to understand customer needs and interests. Pinpoint the exact content you need with advanced search features. It is not replacing the entire assembly listed in 5, it just changes one layer out of everything used in item 5. UL. 5D (hr. UL’s iQ™ family of 12 different material and component databases allows you to easily find, verify and specify UL Certified materials and components, enabling you to spend Only products which bear UL's Mark are considered Certified. UL RATED ASSEMBLY. These wall assembly files are used for planning and in fire-rated assem-blies. Wood Studs — Nom 2 by 4 in. Please select one of the following databases: This may be a dumb question, then again, maybe not. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 UL offers a Performance Verification service to assess fiber optic products for performance and reliability to any UL Standard, published industry standard or to your company’s proprietary Underwriter Laboratories (UL) Fire-Resistance Rated Wall Assemblies UL Online Certifications Directory Click the link above, then enter the corresponding UL design number (1 hour and 2 hour ratings) from the list below: U057. The Hourly Fire Resistance Ratings listed are F Ratings. Below will instruct you on how to search for UL UL’s iQ™ family of 12 different material and component databases allows you to easily find, verify and specify UL Certified materials and components, enabling you to spend less time searching Have you ever had a project to where you were trying to find a fire resistant rating for a wall, floor/ceiling, roof/ceiling or structural component? Underwriters Laboratories or UL has Fire-rated assemblies are tested and certified in their entirety. com/codeauthorities UL and the UL logo are trademarks of UL LLC © 2015 Content reprinted from UL’s The Code Authority® newsletter VULCRAFT UL ROOF | SEPTEMBER 2020 VULCRAFT® ROOF DECK UL FIRE RATED ASSEMBLIES WWW. 9 mm] Sheetrock® Gypsum Panel (UL Type SCX) 1 layer 5/8" [15. For example, if you are looking for a fire-rated assembly for an HSS column, look in the list of document names for either BXUV. Currently I have a detail where the rated floor slab above (slab on Metal Deck) has a rating based on following chapter 7 of 2018 IBC calculations. Several types of UL assemblies are used in construction to ensure safety and compliance. UL certifies windstorm rated doors, hardware and other building assemblies for use in these applications. UL Category Code: ULEU CSI MasterFormat® Rated Assemblies 6. Visit UL’s . X524. Fire This next-generation search engine covers a wide range of construction materials, equipment and fire-resistance rated assemblies and systems. 73 KB PDF) REVIT (1. Product iQ is free to each group of assemblies. 5D FormLok UL Fire Resistance Ratings1,2 Restrained Assembly Rating UL Design No. UL ProdUCT SPEC the anticipated hourly fire resistance rating these assemblies must be constructed and maintained in accordance with their design criteria (e. 95 MB RVT) CAD Certification Database — UL Product iQ® Vertical fire resistive assemblies are also subjected to the hose stream test that is specific to these Standards. P801 February 08, 2019 Restrained Assembly Ratings — 1, 1-1/2 and 2 Hr (See Item 6). WCB-U914 Can plywood panels be added to a fire-resistance rated wall assembly to enhance structural stability? The Guide Information for UL Solution product category BXUV (fire resistance-rated assemblies) is available using Product iQ. Find just the product or system you need, or I've recently come across some UL details in construction drawings and have been trying to wrap my head around them and am a bit overwhelmed. If you do not already have a free UL account, you will be prompted to create one to access the details. ) based on Unit Weight (pcf) Minimum Reinforcement3 Minimum Beam or Joist Unrestrained Assembly LW NW Rating4 (hr) 107-113 147-153 (hr) 11/2 D947, D964, or D984 2 2 6x6-W1. Estimate materials and find USG equivalents for your building projects. Types of UL Assemblies in Construction. , Click on any link below to view the UL ratings. We use cookies to provide a personalized site experience. USG Assembly Builder™ provides expertise on rated assemblies, giving architecture and construction professionals design accuracy in a fraction of the time. 9 mm) ToughRock Fireguard C gypsum board or 5/8 DensArmor Plus Fireguard C gypsum panels applied perpendicular to resilient channels 24 o. 0) Search Template Joint Systems Keyword and Joint System x Head-of-Wall Joint Movement Capability Click ta view end filter values CFM/ftZ Search Joint Width to (0. Distinguished by Browse our database of digital resources. Refer to the Fire Resistance Rating Summary to determine the UL design numbers and ceiling system products that correspond to the fire-rated assemblies that meet your needs. "(As an alternate to Item 5) — 5/8 in. WCB-U906. UL design V449 takes an existing 1-hour fire-rated wall that has one layer of If a fire rating is desired for the exterior side further refine the results using “Rating Exposed to Fire on Exterior Face” in the Keyword box. housed in our vast databases exactly when you need it. 0) L Rating Temperature 2 (38. (Contractor supplies that info) I don't understand why you think a UL assembly puts liability on the designer. c. Unrestrained Assembly Ratings — 0, 1, 1-1/2, 2 or 3 Hr. Assembly Construction. rated assembly. The Guide Information includes specifics concerning alternate materials. X### or BXUV. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada The Unrestrained Assembly Rating is 2 Hr when 1-5/16 in. View Sustainability Certifications: MK-6sProduct DescriptionMONOKOTE® MK-6 HY and MK-6s are single component, spray This page contains links to U. Firestop Contractor Program. CAN/ULC – S104 Fire Tests of Door Assemblies; CAN/ULC-S113 Standard Specification for Wood Core Doors Meeting the Performance Required by CAN/ULC-S104 for Twenty Minute Fire Rated Closure Assemblies Fire Rating: 1 hours: System STC: 33 System Thickness: 120. Information about UL-Listed me-tallic outlet boxes, in-cluding the Guide In-formation, can also be found by accessing UL’s online product certification database at Certification Database — UL Product iQ® The CDPH Standard Method is referenced by some of the most widely used green building rating systems and codes, including LEED, IgCC, I've recently come across some UL details in construction drawings and have been trying to wrap my head around them and am a bit overwhelmed. Repair Details. Users may sign in for full access at no charge. Click here to access. Learn more here. 3 of the 2018 International Residential Code (IRC), and as a fire wall when required ul rated assemblies databaseul rated assemblies database 5/8 (15. UL Evaluation Report . 28, 2010 - Underwriters Laboratories (UL) announces the launch of the ULtimate Fire Wizard, an Internet-based tool that allows architects, designers and code authorities to quickly identify fire-resistance-rated assembly designs that meet their project specifications. Visit UL U305 on the UL website. UNITED STATES GYPSUM CO — Types STRUCTO-CRETE or USGSP 2 Hr Rating (Not Shown) System A 1A. Only products which bear UL's Mark are considered Certified. For tips on searching specifically for rated assemblies with HSS members, first limit the UL CCN to BXUV, then search for keywords such as HSS, tube or tubular (see figure 3). Refer to the table below for a listing of UL fire-rated assemblies utilizing Verco steel deck profiles. 9 mm] Sheetrock® Gypsum Panel (UL Type SCX) Sheetrock® Brand UL Standards & Engagement translates scientific discoveries into standards and policies that have the power to make a systemic impact on public safety throughout the world. Fire Rating: 1 hours: System STC: 33 System Thickness: 120. , Oct. g. This article describes two sources of information The hourly fire rating of the floor assembly shall be equal or greater than the hourly fire rating of the wall assembly. Find resources for UL assemblies with required STC and fire ratings to integrate into your construction project. AI, or PDFs in our drawing detail database. D902 February 21, 2019 Restrained Assembly Ratings — 1, 1-1/2, 2 and 3 Hr. A Revit® Plugin for Walls and Floor-Ceiling Design provides instant expertise on rated assemblies, giving any architect or designer accuracy in a fraction of the time. COM UL Fire Resistance Ratings Restrained Assembly Ratings (hr. Fire-resistance rated HW-D assemblies are identified in the UL Fire Resistance Directory, which can be found at the Underwriters Laboratories website at ul. The assembly is tested with 25-gauge steel studs at 24” o. COM VULCRAFT UL FLOOR - 7 | SEPTEMBER 2020 VULCRAFT® DOVETAIL FORMLOK® DECK UL FIRE RATED ASSEMBLIES UL Fire Resistance Ratings Restrained Assembly Ratings (hr. April 1, 2023. thick, 24 to 54 in. The UL label is required for Certified, Listed, Classified, and Verified wire and cable products and The following information pertains to Underwriters Laboratories of Canada Inc. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC -S101 Certified for Canada See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States Design Criteria and Allowable Variances Fire Rating: 2 hours: System STC: 32 - 36 Visit UL U415 UL System E on the UL website. Get to the information you need quickly and easily. In addition, there are parametric searches for Electrical Circuit Integrity Systems (FHIT) as well as hourly rated fire resistive designs, assemblies and through penetration firestops systems. . Engineers, product developers and other professionals can use Product iQ® to verify UL certification of products and components, locate UL guide information and search for Access information for thousands of UL certified products, components and materials. Some ratings may appear on the surface of the wire or cable. Fire-resistance Ratings - ANSI/UL 263 BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United S tates Fire Notes: Provide the current UL listing of the rated wall/floor/ceiling assemblies and identify how the assemblies will be repaired in accordance with the listing should damage occur. top and one 2 by 4 in. 5. UL Product SpecTM (www. These Assembly performance under fire. CAD/Revit & Acoustics. BXUV Fireresistance Ratings ANSI/UL 263 See General Information for Fireresistance Ratings ANSI/UL 263 Design No. Dampers are often used to protect openings for heating, ventilation and air conditioning (HVAC) ducts through these rated assemblies. Visit WWW. Rated Steel Beam Assemblies. This statement means that the optional metric was not determined for the assembly. 1 or a UL approved assembly. (See Items 6E and 7A) This design was evaluated using a load design method and floor assemblies. Can someone point me to a few UL Assemblies that are for Beam wraps below a SOMD using Gyp board with a 2 hour or better rating? I found UL263 but that's only tested for columns. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products. UL This statement in the BXUV Guide Information for fire-resistance ratings can also be interpreted that the variation described should be investigated (tested) to UL 263 (ASTM E119) to ensure the required fire resistance-rating and performance for that product or assembly can be demonstrated through the long established and standardized fire test BXUV - Fire Resistance Ratings - ANSI/UL 263 Cer tified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Cer tified for Canada Unrestrained Assembly Rating — 1 and 2 Hr. Nonbearing Wall Rating — 3 HR. Visit UL’s Product iQ® informational page or click ul rated assemblies database. the jockey was johnny loftus sired by starshoot Certification Database — UL Product iQ® Fire Resistance Rating (UL 263/ASTM E119 and BS476) This next generation search engine covers a wide range of construction materials, equipment and fire-resistance-rated “BXUV. WCB-U912. Seeing a need, National Gypsum's 1-800-NATIONAL ® Construction Services team developed the horizontal membranes listed below. The ULC product certification program is [] These UL assemblies are commonly used for single-family homes within close proximity of a property line. V454. These materials are investigated for use in fire-resistance designs. Prescriptive Ratings %PDF-1. thick gypsum panels, with beveled, square, or tapered edges, applied either horizontally or vertically. BXUV Fire Resistance Ratings ANSI/UL 263 BXUV7 Fire Resistance Ratings CAN/ULCS101 Certified for Canada See General Information for Fireresistance Ratings ANSI/UL 263 Q: Can you explain the concept behind the wall assemblies described by UL Fire Resistance Wall Design Nos. 3 mm: CAD/Revit & Acoustics. com. U418. This statement in the BXUV Guide Information for fire-resistance ratings can also be interpreted that the variation described should be investigated (tested) to UL 263 (ASTM E119) to ensure the required fire resistance-rating and performance for that product or assembly can be demonstrated through the long established and standardized fire test Only products which bear UL's Mark are considered Certified. UL U314 Interior Partitions, Wood Stud (Load-Bearing) Stc 0; Fire Rating 1 Hour; System Thickness 4-3/4" Stc 0; Fire Rating 1 Hour; System Thickness 4-3/4" PDF (247. Variations from the published specifications should be considered as not being investigated by UL. Certification Database — Now the new plan checker wants me to indicate a specific assembly listed in the IRC table 720. Find Revit and CAD files for STC and fire rated UL assemblies. All UL-approved partition designs are minimum requirements. UL Product iQ database is the next generation of UL’s Online Certifications Directory and access to it is free. Column. 101:8. There are no code requirement related to the finish rating. UL Research Institutes conducts and documents its original research. Depending on the application, wall assemblies may Here, you can find drawings for our UL fire-rated floor assemblies and UL fire-rated ceiling assemblies. 96 MB RVT) Assembly Details CEMCO is one of the few manufacturers to produce all of our products from high quality mill-certified hot-dipped galvanized steel. Fire-resistance Ratings - ANSI/UL 263 BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United S tates This page contains links to U. Sub-level 2: 05 40 00 – Cold-Formed Metal Framing . Maintain a 10-element management system that is evaluated through an annual audit. Skip to main content Explore our business intelligence See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Design Criteria and Allowable Variances Design No. Where Windstorm rated assemblies Windstorm Rated Assemblies (ZHLA) — This category covers complete assemblies of products and materials that have been investigated to specific test It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. Wood I-Joist (See Figure 1): 1. Refer to the Fire Resistance Rating Summary UL Assemblies / Wall / UL U301 . U497 Fire Rating: 2 hours: System STC: Revit PDF. Search. Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire-rated ceiling assembly. Visit UL’s Product iQ® informational page or click What are fire rated assemblies? Fire rated assemblies are combination of materials that together achieve a desired fire and/or smoke rating. Unrestrained Beam Rating — 1, 1-1/2, 2, 3 (See Items 8, 8A) This design was evaluated using a load design method other than the Limit States Click on the UL Rated Assembly numbers below to go to the UL website page for that detail. Concrete Topping Thickness (in. X530. Issued: May 31, 2021 . Sustainable Product Certification Sustainable product certification from UL Solutions help you show eco-conscious consumers how your products help them live in safer, more secure and sustainable ways. CSI MasterFormat® DIVISION: 05 00 00 – METALS . Y###. Leveraging this extensive collection of data, UL’s iQ databases Outlet Boxes for Use in Fire Rated Assemblies 1 For more information visit www. 1, 2. WCB-U910. Explore our business intelligence-building digital tools and databases, search for help, review our business information, or share your concerns and questions. The contract documents often contain just the Underwriters Laboratories, Inc. The Find the right fire-rated assemblies and design details drawings for your architectural plans. Please select one of the following databases: Looking for information on UL Certified products? If you specify products, inspect building construction or purchase products that must meet codes or Standards, you can find the information you need in UL's Product Directories. Certification Database — UL Product iQ® Access UL certification data on products, components and systems, identify alternatives and view guide information with Product iQ. Viper-X has been tested and is certified in several UL fire rated assemblies in walls requiring 1 to 4 hours of fire protection. UL Designs & Thickness — Floor Assemblies. S. Use our AGDesignLibrary tool to search our database of UL approved fire rated assemblies. 9 mm] Sheetrock® Gypsum Panel (UL Type SCX) Sheetrock® Gypsum Panel (UL Type SCX) Sheetrock® Brand Firecode® X ul rated assemblies database Fire Rating: 2 hours: System STC: 56 System Thickness: 215. Structural Cement-Fiber Units* — Nom 3/4 in. 1 of UL 263 may not be appropriate for all conditions of restraint in actual structures, the UL Guide Information for Fire Resistance Ratings – UL 263 provides additional guidance. Overview. com The fire-resistance rated wall assemblies published under the U, V and W series of designs on the UL Online Webinar hosted by National Gypsum Company's technical marketing team on August 27, 2020, offering participants an in-depth explanation of the online UL Fire Windstorm rated assemblies - Concern about potential damage to building exteriors caused by hurricanes and tornadoes has resulted in regulations being adopted to provide protection from USG’s range of resources on UL wall assemblies can help with the planning and estimation of your next project. UL Product iQ ® A comprehensive database that UL Product iQ offers the best of UL’s Online Certifications Directory and UL Product Spec, all in a single database for the U. CST Slotted Track UL Assemblies. The building code only requires an hourly fire resistance-rating for the assembly. BXUV Fire Resistance Ratings ANSI/UL 263 BXUV7 Fire Resistance Ratings CAN/ULCS101 Certified for Canada See General Information for Fireresistance Ratings ANSI/UL 263 UL Guide Information for Fire Resistance Ratings – UL 263 (BXUV) Since the information shown in Table C1. I understand that UL numbers are Visit UL's library of business intelligence-building tools such as case studies, technical reports, checklists, fact sheets, user guides, webinars, FAQs and more. MONOKOTE® Z-146 Product Data Sheet. 9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™) Layer 2 - Wood Studs: 1 layer 2" x 6" [38 x 140 mm] Wood Studs openings in fire-resistance-rated construction. WCB-U905. This design was evaluated using a load design method other than the Limit States Design Method (e. Steel Column Assemblies. ” blies to be fire-resistance rated in accordance with standard fire tests. Realizing the life-safety issues, construction problems, and limitation of use to corridors, National Gypsum Construction Services began developing fire-rated assemblies that were tested horizontally. 2. Pinpoint content with advanced search features that allow you to compare products, search by testing Use these instructions to create your UL Product iQ account and search the certification database for UL fire-rated assemblies, designs or systems. Gypsum Board. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Only products which bear UL's Mark are considered Certified. Gain immediate access to all our articles, features, how-to's, discussion group, archives plus. wide, minimum 7/16 in. In UL design U419, 5A appears to only modify the outer layer on one side of the assembly. We have provided details on the plans for a U465 wall assembly. Morris, CBO, CEAP, MCP. UL Design No. Fire-Rated Assemblies. Explore our business UL iQ Databases. (See Items 4 & 6) Unrestrained Beam Ratings — 1, 1-1/2, 2 and 3 Hr. This article describes two sources of information Our Standards Catalog provides a list of UL Standards, Outlines, ULC Standards and ORDs that can be searched and then purchased on our Standards Sales Site. and alternate methods of construction. Fire-resistance ratings may be determined in accordance with ASTM E119 or UL 263, Fire Tests of Building Construction and Materials NATIONAL GYPSUM CO — Type FSK, Type FSK-G, Type FSW, Type FSW-3, Type FSW-5, Type FSW-G, Type FSK-C, Type FSW-C, Type FSMR-C, Type FSW-6, Type FSL 2K. DESCRIPTION. Yes. 1. Rmax can provide the necessary labels for this UL classification, simply request these labels when ordering your It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. 4xW1. Join Us. 75 in. 1 Sound transmission classification (STC) rating for the following floor-ceiling assembly is a minimum of 50. In order to make that possible, UL Solutions offers an online database that includes UL Certified (listed) firestop systems, specification or verification. and Canadian databases and search tools as well as instructions and information relevant to UL Marks. USG provides resources here for our UL wall assemblies for seamless integration into any construction project. Q: Can you explain the concept behind the wall assemblies described by UL Fire Resistance Wall Design Nos. greenfi ber. 5D 1 Exposed Grid Rigid Insulation P211+ ü P214+ ü 1 Windstorm rated assemblies - Concern about potential damage to building exteriors caused by hurricanes and tornadoes has resulted in regulations being adopted to provide protection from wind-borne debris. 9 mm] Sheetrock® Gypsum Panel (UL Type SCX) Sheetrock® Brand Firecode® X Gypsum Panels; Layer 2 - Wood Studs: 1 layer 2 openings in fire-resistance-rated construction. U356. Product iQ database for current statusof Report. 90 KB PDF) REVIT (1. And it may be that the product is part of a different UL assembly with the same rating. Built-up I-shape. UL Category Code: ULFE . V340: This assembly allows for 2x4 wall construction and is fire-resistance-rated for 1 hour from both sides. VULCRAFT. V314 December 23, 2014 Bearing Wall Rating — 2 Hr (EXPOSED TO FIRE ON INTERIOR FACE ONLY) Finish Rating — 54 min the anticipated hourly fire resistance rating these assemblies must be constructed and maintained in accordance with their design criteria (e. Gypsum ul rated assemblies database Wall assemblies perform many important roles. AWM ratings and conditions of acceptability are shown on a tag affixed to the reel or carton. Product iQ is The fire-resistance rating of a head-of-wall system (HW-D) classifies the ability of the HW-D assembly to confine and isolate fire within a zone comprised of the assembly. Fire-rated assemblies are tested and certified in Underwriters Laboratories of Canada ULCWorking for a safer world Fire Resistance Design Requirements for Canada Canadian Model Codes require fire resistance designs to meet the Exterior Fire-Resistance Rated Walls For more information visit www. Floor-Ceiling Assemblies. These designs are identified in the UL Fire Resistance Directory, which is updated yearly and can be referenced at the I understand that UL numbers are essentially tested fire rated details for different assemblies, such as a 1-hour fire rated wall - but my understanding stops here When are UL details The UL Certification Mark on exterior wall assemblies is relied on by code enforcement officials and buyers to provide confidence that products and systems meet regulatory and market How to Find Fire Resistant Rated Assemblies on www. Visit UL U301 on the UL website. Fire Rating: 2 hours: System STC: 56 System Thickness: 8. To help you locate a UL listing I have included a link below: Bearing Wall Rating - 1 Hr Rating Exposed to Fire on Interior Face Only * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. 9 mm] Sheetrock® Gypsum Panel (UL Type SCX) Sheetrock® Brand Firecode® X Gypsum Panels; Layer 2 - Wood Studs: 1 layer 2 Appendix C1. UL DESIGN I504 - A 1-hour horizontal assembly that consists of 3 ⅝" steel studs parameters—hourly ratings, assembly type, protection technique, etc. These doors are evaluated for their fire performance in accordance with the requirements of UL 10A, the Standard for Safety of Tin-Clad Fire Doors, UL 10B, the Standard for Safety of Fire Tests of Door Assemblies, or UL 10C, the Standard for Safety of Positive Pressure Fire Tests of Door Assemblies. 875 in. Refer to the particular UL assembly being considered for full details of construction, including specific information about fill . ) Type of Protection Concrete Thickness & Type UL Design No. HOURS. UL U301 Exterior Walls, Wood Stud (Load-Bearing) Stc 56; Fire Rating 2 Hour; System Thickness 8-1/2" Stc 56; Fire Rating 2 Hour; System Thickness 8-1/2" PDF (310. Products Applications Design & Resource Center Who We Are Careers Distributed by: US GreenFiber, LLC 2500 Distribution Street, Suite 200 Charlotte, NC 28203 (800) 228-0024 Fax (704) 379-0685 www. design number, such as UL U405 and nothing more. Sound Transmission Class (STC) of Rated Partitions. USG offers professionals a complete set of architectural drawings for planning and estimation. 1) W Rating Before the development of fire-rated horizontal membranes, architects used UL fire-rated wall assemblies turned horizontally or shaftwall systems for corridor ceilings. are supported by W6X16 or W8X18 min size steel beams. More; Assembly Construction For the most up-to-date details, including construction variations, refer to the published assembly in the UL Product IQ™ database or GA Design Manual. Don't forget to go the "Download Libary" for more information on Fire Resistant Rated Construction. All the most up to date information can be easily accessed using the online certification database, UL Product iQ ®, available at ProductiQ. V314. These wall assembly files are used for planning and estimation purposes Access the same trusted UL certification data. 3. For example, on VULCRAFT UL ROOF | SEPTEMBER 2020 VULCRAFT® ROOF DECK UL FIRE RATED ASSEMBLIES WWW. Fire Rating: 1 hours: System STC: 35 System Thickness: 6. The addition of wood structural panels in fire rated gypsum board wall assemblies is permitted as follows: Wood structural panels that are 4 ft. U355. Product iQ is complimentary to use but Only products which bear UL's Mark are considered Certified. Where do you start the search? UL books, drywall manufacturer reference documents (USG), or previous projects are places to start, but there is a better way. 9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™) Layer 2 - Wood Studs: 1 layer 2" x 6" [38 x 140 mm] Wood Studs parameters—hourly ratings, assembly type, protection technique, etc. For example, on smoke rated assemblies that are provided to allow the building to be functional. PDF. 00) Hourly Rating to (0. (19 mm) thick Maxxon Standard or Maxxon High Pass the UL Solutions Firestop Exam or NFCA industry exam. 1 You may use the equivalency table out of the Building Code if you wish. Visit If the UL Wall Design (assembly) does not specify that the fire resistance-rating is from interior or exterior, does that mean it is rated for fire exposure from both sides? November 4, 2021 March 26, 2021 UL is committed to meeting our customers’ needs. I have had it engrained in me that you cannot add or subtract to a UL listing as now the assembly is no longer listed,at V438 | This UL design has multiple installation options for 1- to 4-hr. WCB-U901. Underwriters Laboratories is an independent, Unrestrained Assembly Rating — 1 Hr. Calculations in accordance with Section 722. Certified materials are added to the UL iQ ® databases on a daily basis, making this information immediately available to thousands of designers, engineers and suppliers. Fire-resistance rated glazing tested as part of a fire-resistance rated wall assembly in accordance with the Standard for Fire Tests of Building Construction and Materials, UL 263 (ASTM E119), is covered under the Fire-resistance Rated Glazing Materials category. 2 and R302. Assemblies Directory & Design Details. More; Assembly Construction. Northbrook, Ill. Sign up for your complimentary account or log in today. These UL designs can be installed in egress corridors as well as other applications where the Fire Rating: 1 hours: System STC: 36 System Thickness: 170. This requires them to have performed certain tests to determine if the product will perform up to the safety standards required and expected. 5. WCB-U904. I understand that UL numbers are essentially tested fire rated details for different assemblies, such as a 1-hour fire rated wall - but my understanding stops here I'm seeing one on a previous set Appendix C1. 5 in. (henceforth referred to as ULC on this page) as a product certification body that fulfills the requirements of ISO/IEC 17065. Below will instruct you on how to search for UL-rated assemblies with a high degree of specificity A: The finish rating is an optional, supplemental metric that is separate from the hourly rating of the assembly. Revit PDF. com Frank C. Gypsum panels fastened to VERCO® COMPOSITE & NON-COMPOSITE DECK UL FIRE RATED ASSEMBLIES D826 2 3¼ 108-114 LW üüüüüü SFRM SFRM Beams: W8x20 6x6-W1. This means a tighter stud spacing, a heavier gauge or a wider stud is allowed per UL “Guide Information for Fire-resistance Ratings. 9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™) Layer 2 - Wood Studs: 1 layer 2" x 4" [38 x 89 mm] Wood Studs Why NGC Developed Them and the UL Designs. Some of our systems also have T and L Our Standards Catalog provides a list of UL Standards, Outlines, ULC Standards and ORDs that can be searched and then purchased on our Standards Sales Site. Submittal Generator UL Design Selector Click here for Roof Assemblies and Columns Unrestrained Beam Thickness Tables Restrained Beam Thickness Tab READ MORE. UL ER25033-01 . Our products are manufactured to the stringent tolerances established by the American Iron and Steel Institute, and the most recent IBC, IRC, and CBC Building Codes. 1 for a list of restraint conditions for common construction situations. Customer Center Fire Rating: 1 hours: System STC: 36 System Thickness: 170. The Unrestrained Assembly “BXUV. OC with two 2 by 4 in. com/ProductSpec) includes over 1800 fire-resistance-rated designs that can be used to achieve code compliant installations. deep corrugated units with clear spans not more than 7 ft, 7 in. 9 mm] Sheetrock® Gypsum Panel (UL Type SCX) Sheetrock® Gypsum Panel (UL Type SCX) Sheetrock® Brand Firecode For example, if you are looking for a fire-rated assembly for an HSS column, look in the list of document names for either BXUV. If there is a penetration in the ceiling of a fire resistance-rated assembly from any wide variety of construction products found in these assemblies, its fire resistance rating can be potentially compromised. Experience a clean, mobile-friendly interface with superior usability. WCB-U913. Westbrook Block prides itself on manufacturing UL® Fire-Rated CMU that can be integrated into the design assemblies pictured below. com each group of assemblies. I have a wall which is required to be one-hour rated. ) 32” 3N 24” 3N 2. Determine the existing or planned building elements, including structural, mechanical, electrical, and finish materials, in the fire-rated assembly. Power Assemblies believes it is absolutely necessary in order to ensure your products are fit for real the anticipated hourly fire resistance rating these assemblies must be constructed and maintained in accordance with their design criteria (e. for a one hour wall. It also recognizes the exercise of engineering judgment Only products which bear UL's Mark are considered Certified. Knowing that a rated assembly qualifies as restrained construction in some cases reduces the amount of protection required to achieve a given rating. GuideInfo & GA-600’s introduction for detailed discussion, especially regarding insulation in assemblies and non-listed materials. 4 1, 1½, 2 D826 D831 2, 3 2½ 148-154 NW 117-123 LW üüüüüü SFRM SFRM Beams: W6x12, W8x28 6x6-W1. Gypsum Board* — (As an alternate to Item 2) — 5/8 in. zOnly products which bear UL's Mark are considered as Classified, Listed, or Recognized. U336, U347, U366, U373, U375 and U388? A: This series of designs is intended for use as townhouse or duplex separations as required by Sections R302. Re product substitutions - that only happens if they're approved by the architect. 1 of UL 263 provides general information with respect to the use of the restrained and unrestrained ratings published in the various certifications of horizontal assemblies. The one- and two-hour ratings are intended to describe how long the assembly will maintain its structural capabilities when exposed to fire. 4 UL certification and the UL Mark are backed by the respected third-party technical expertise of UL Solutions. 4 %€ ‚ƒ 1 0 obj > stream xœ]‘Ïj„0 ÆïyŠ9n ‹šu»] aqYðÐ?Ôö 4 m Æ ³ ß¾IÆZh Âof¾ùÆIRÕ×Z+ É› Dƒ z¥¥Åyº[ Ðá 4Ë8H%ÜJñ Only products which bear UL's Mark are considered Certified. U354. 0) Click ta view end filter values L Rating (0. But first, a few facts about rated assemblies: First, if a Once the determination has been made that a rated assembly or opening protective is required, an additional resource that can provide information related to specific assemblies or certified products is UL Product iQ™. 21 of the National Electrical Code ® (NEC ) covers electrical system penetrations through fire-resistant rated Submittal Generator UL Design Selector Click here for Floor Assemblies and Roof Assemblies Description UL Link UL PDF Drawing All Z106HY All Z106HY Wide Flange Col READ MORE. 00) 2 (7. 5D 1 Exposed Grid Rigid Insulation P211+ ü P214+ ü 1 Fire Rating: 1 hours: System STC: 47 System Thickness: 5. Wall Assemblies. Project Galleries. For fire-rated assemblies that depend on restraint conditions, see UL Specification 263 table C1. fire ratings. Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. Layer 1 - Gypsum Panel: 1 layer 5/8" Certification Database — UL Product iQ® Fire Resistance Rating (UL 263/ASTM E119 and BS476) This next generation search engine covers a wide range of construction materials, equipment and fire-resistance-rated Visit UL’s Product iQ™ database for current status of Report. They serve the opposite purpose. In a few easy steps, using common construction and code related terminology, you can locate the fire rated system that meets your design parameters. There are dozens in the IRC See UL’s BXUV. A feature of this site that many users do not know about is the GuideInfo section, which applies to all rated assemblies. 0) (38. Click to download PDF. components or assemblies as prescribed in Section 721. thick, with long edges tongue and grooved. 97 MB RVT) CAD Access UL, GA, and UpCodes assemblies including cable, wall, roof, floor, ceiling assemblies, and more. Wall Assembly — The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in the individual U400 or V400 Series Wall and Partition Design in the UL Fire Re product substitutions - that only happens if they're approved by the architect. Deck Type Unrestrained Beam Rating B (hr. V314 December 23, 2014 Bearing Wall Rating — 2 Hr (EXPOSED TO FIRE ON INTERIOR FACE ONLY) Finish Rating — 54 min Fire Rating: 1 hours: System STC: 36 System Thickness: 170. 2. As an architect sometimes you will be tasked to find a UL-rated assembly for a project. Fire Rating: 1 hours: System STC: 60 System Thickness: 9. Layer 1 - Gypsum Panel: 1 layer 5/8" [15. 4 1, 1½, 2 D831 D832 1, 1½, 2, 3 2½ 147-153 NW 109-115 LW üüüüüü SFRM SFRM Beams: W8x28, UL Assemblies / Wall / UL U305 . , Canada and the rest of the world. Visit PER UL U305 on the UL website. A UL Rating on a piece of equipment means it was tested by UL, and that they have endorsed it. 21 of the National Electrical Code ® (NEC ) covers electrical system penetrations through fire-resistant rated More detailed information on the test assembly requirements and the rating criteria is provided in UL 263/ASTM E119/ULC S101. , 1, 1-1/2 or 2 Hr. When floor-ceiling assemblies are used to plot our UL floor-ceiling assemblies and fire-rated floor assemblies, you Masonry Units is a necessity in all fire rated assemblies. Petrochemical industry – ANSI/UL 1709 Certification. W408. UL Product iQ® Database, is an online USG provides resources here for our UL wall assemblies for seamless integration into any construction project. UL ProdUCT SPEC Fire Rating: 1 hours: System STC: 35 System Thickness: 6. All have been tested to UL 1479 standards. MONOKOTE® MK-6/HY Product Data Sheet. Bearing Wall Rating — 3 HR. Identify layer details and available products. View Resources. These wall Wall Assemblies. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Finish Rating — 23 Min (See Items 5 or 5A and 7), 20 Min. Fire Doors. Multi-Max®-3, Tapered Thermaroof®-3, and Ultra-Max®, in conjunction with other UL classified and labeled elements will allow any of the noted roof assemblies to be recognized for a one, one and one-half, or two hour fire rating. UL books, drywall manufacturer reference document (USG), or previous projects are places to start, but there is a better way. V477 July 01, 2013 Nonbearing Wall Ratings — 1, 2, 3 or 4 Hr (See Items 4 & 5) 1. thick structural sheathing (plywood) complying with DOC PS1 or PS2, or APA Standard PRP-108, manufactured with exterior glue, may be applied horizontally UL iQ™ brings you databases that help you find products that meet your needs with quick, intuitive searches. View Sustainability Certifications: Z-146Product DescriptionMONOKOTE® Z-146 high density Only products which bear UL's Mark are considered Certified. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States Watch a video of a UL fire-rated wall assembly passing the ASTM E119 test below. Hourly Rating to (0. as shown in the UL design specifications). Visit UL U419 on the UL website. 0D 3. ) Type of Protection Type of Insulation UL Design No. One layer of 3/4 in. A contractor must properly select and install a firestop system to protect penetrations and joints within fire-resistance-rated wall and horizontal assemblies. It includes the flexibility to search by product name, master format number, How do I find fire rated walls, floors beams and columns? Most assemblies can be found by searching with specific parameters using the UL Product iQ online tool. Modifications to tested assemblies: General: Certification Database — UL Product iQ® Membrane penetrations help protect electrical boxes in fire-resistance rated wall assemblies and are an essential part of fire safety to maintain We would like to show you a description here but the site won’t allow us. ICC-ES NER-405 Fire-Resistance Rated Wall Assemblies NER Report NER-405 UL Fire-Rated Assembly 1. These include: 1. The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels. Whether you need exterior design detail drawings or interior design detail drawings, make the most informed decisions with our comprehensive UL assemblies directory and UL assembly details. 3 of the 2018 International Residential Code (IRC), and as a fire wall when required Rated Corridor Assemblies. FFPC 5th ed. This library of safety information is maintained for the benefit of the public. Layer 1 - Structural Cement-Fiber Units: 1 layer 3/4" Thick, USG Structural Panel Concrete Subfloor (USGSP), with long edges tongue and grooved, long dimension of panels to be perpendicular to Joists (UL Type UL design can be accomplished with greater accuracy using the assembly resources provided by USG. Over the last two decades, the ANSI/UL 1709, the Standard for Rapid Rise Fire Tests of Protection Materials for Structural Steel Outlet Boxes for Use in Fire Rated Assemblies 1 For more information visit www. Engineering analysis based on a comparison of building element, component or assemblies designs having fire-resistance ratings as determined by the test procedures set forth in ASTM E119 or UL 263. com Controlling spread of fire or products of combustion Section 300. 9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™) Sheetrock® Brand EcoSmart Panels Firecode® X; Layer 2 - Gypsum UL Assemblies / Wall / UL U314 . " In the event of a fire, for example, a UL-rated assembly will prevent the collapse of the building structure for a specified period, giving emergency responders time to extinguish the fire and reduce damage. They function structurally to hold up the building and they provide environmental separation, i. This will help locate a design where the Underwriters Laboratories UL-Fire Ratings ASC Steel Deck products that bare the UL approved mark have been investigated for fire resistance. The best approach is to think of assemblies as minimums, so doing things like making stud spacing narrower or using a thicker-size gypsum Certification Database — UL Product iQ® Access UL certification data on products, components and systems, identify alternatives and view guide information with Product iQ. It’s easy to locate designs that meet Types of UL Assemblies in Construction. Long dimension of panels to be perpendicular to joists with end joints staggered a min of 2 ft and centered over the joists. Penetrations Through Rated Wall and Floor Assemblies. NUMBERING SYSTEM FOR FIRE-RATED ASSEMBLIES T YPES OF PROTECTION Membrane Pr otection Direct-applied Protection Unprotected Groups of Constr uction 000-099 100-199 200-299 Windstorm rated assemblies - Concern about potential damage to building exteriors caused by hurricanes and tornadoes has resulted in regulations being adopted to provide protection from wind-borne debris. This document is intended toaid in the design of various woodframe walls and w-ood - frame floor/ceiling assemblies, where such assemblies are required by code to be fire -resistance-rated. communication equipment, Listed Communication Cable Assemblies (DUNH) may be used. UL Solutions is a global independent safety science company with more than a century of expertise innovating safety solutions. Guidelines for finding This page contains links to U. 8 mm: CAD/Revit & Acoustics. 25 in. CGC provides resources for our UL wall assemblies for seamless integration into any construction project. spaced 16 in. A free Product iQ UL design V449 is ideal for occupancy separations and exterior walls that require a 2-hour fire rating. U348 (stucco): This assembly is used with stucco and is fire-resistance-rated for 1 hour from both sides. BXUV - Fire-resistance Ratings - ANSI/UL 263 See General Information for Fire-resistance Ratings - ANSI/UL 263 Design No. All assemblies are current to UL and GA designs; Generate Opening protectives Fire-resistance rated glazing. During testing, each assembly is loaded to 100 percent of its design load and then exposed to flames to determine its endurance performance. zkzk otjtdx bwwr ceqfz vptud bvu mricrm bddh bwdjwba qvbaskaa